| Product Name: |
APM-LA - 5000 ~ LA -10000 |
| Description: |
Operation Pressure : 150 -220 PSI
Rejection : >97% (Organic, colloids, bacteria, and pyrogen are above 99.9% rejected.)
Recovery Rate: 50% ~ 75%
Model# |
Flow Rates (GPD) |
R.O Modules
(Model x Numers) |
R.O Pump / Voltage |
Pre - Filter |
Dimensions (cm)
& Weight (kg) |
LA - 6000
LA - 7500
LA - 9000 |
6000
7500
9000 |
4040*2
4040*3
4040*4 |
3HP,220V/380V
5.5HP,220V/380V
5.5HP,220V/380V |
TK10 * 1
TK10 * 1
TK10 * 1 |
210*70*178
210*70*178
210*70*178 |
Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4
|
| Features: |
a. Automatically operates and PLC control device.
b. Automatic flush device.
c. Low-pressure protection switch.
d. Product Hi-level control.
e. Over - heat protection device for pump.
f. Concentrate recycle-flow regulator.
g. Digital feed/ product water quality meter.
h. Operating pressure set-up device.
i. Automatic power shut-off device if pre-treatment system is in regeneration process.
j. Chemical cleaning system.
k. All # SUS 304 made skids except the RS-series.
l. Includes one standard Hi-pressure R.O Pump; optional two parallel Hi-pressure R.O Pumps are also available.
|
|
|
| Here are the details for APM-LA - 5000 ~ LA -10000, Reverse Osmosis Plant. It includes model, name, description and specification for APM-LA - 5000 ~ LA -10000, Reverse Osmosis Plant. Related Keywords : Industry Ro Sytem, Fluid Filtration Equipment, RO System, Chemical Cleaning System, R.O Pump, Water Filtration, Water Treatment, Water Purification, Filter Equipment, Reverse Osmosis Plant, Reverse Osmosis, RO Plant |
|
|