Air Power Master International Corp.
Air Power Master (APM) is a manufacturer of fluid filtration equipments and accessories (liquids filter, cartridge filter, bag filter, sand filter, filter housings, water treatment), and is also an authorized distributor of GRACO INC. and GEM- U in Taiwan. Established in 1991,APM helps customers solve difficult manufacturing problems, increase productivity,improve quality and reduce costs.
Home
Company Profile Product Line New Product Contact us
Categories  > Sand Filters
 
( APM Sand Filter Housing )
APM Sand Filters are designed for countries or areas where water quality is an urgent problem to solve. Made by stainless steel 304 or 316, all APM Sand Filters are electropolished for best surface finish and easier housing cleaning. Design pressure is up to 150 PSI for most industries and household applications. There are two choices for backwashing: manual operation or automatic operation. Manual operation filters equipped with a multi-port valve with handle. Users use the handle to switch between three modes as necessary: backwash, rinse or filtration. An automatic control device is installed on the automatic filter, the operation is monitored on elapsed time set by user. With the regular backwash process, automatic filters assure the user of high quality water.

APM Sand Filters allow for various filter media, such as coarse gravel, fine sand, silica sand, manganese greensand, granular active carbon, ion exchange resin, ceramic ball, energetic stone. APM Sand Filters are ideal for treatment of drinking water, process water, cooling water, and cultivating water.
Categories  > Industry Ro System
 
( APM-LA2 - 12000 ~ LA2 - 18000 )
Operation Pressure : 150 -220 PSI
Rejection : >97% (Organic, colloids, bacteria, and pyrogen are above 99.9% rejected.)
Recovery Rate: 50% ~ 75%

Model#

Flow Rates (GPD)

R.O Modules
(Model x Numers)

R.O Pump / Voltage

Pre - Filter

Dimensions (cm)
& Weight (kg)

LA2 - 12000
LA2 - 15000
LA2 - 18000

12000
15000
18000

4080*4
4080*5
4080*6

5.5HP,220V/380V
5.5HP,220V/380V
5.5HP,220V/380V

TK10 * 1
TK10 * 1
TK10 * 1

210*70*178


Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4
Categories  > Industry Ro System
 
( APM-DW-RO-250UO3 DW-RO-800UO3 )
Operation Pressure: 150 - 220 PSI
Rejection : >90(Organic,colloids,bacteria,and pyrogen are above 99.9% rejected.)
Recovery Rate: 50 ~ 75%

Model

DW-RO-2500U03

DW-RO-500U03 DW-RO-800U03

Feed Pump

1/2HP

1/2HP 1/2HP

Iron Removal Filter

MS-15L SS-15L

MS-25L SS-25L MS-45L SS-45L
Activated Carbon Filter AC-15L AC-25L AC-45L
Softener (include Brine Tank) SD-15L SD-25L SD-45L
RO System SA-1500 SA-3000 SA-6000
UV Sterilizer S5Q-P S8Q-P S8Q-P
Ozone Generato OWA-250 OWA-350 OWA-350
Distribtion Pump Stainless Steel Stainless Steel Stainless Steel
Dimension Length:170cm
Width:60cm
Height:170cm
Length:170cm
Width:60cm
Height:170cm
Length:170cm
Width:60cm
Height:170cm


Feedwater Conditions
* Feed Water Pressure=1kg/cm2~3kg/cm2
* Chlorine = < 0.5 ppm
* Total Hardness = <150 ppm
* Turbidity =< 2
* Fe = < 0.1 ppm
* Flow Rate > 1 T/hr
Operation Pressure:150~220PSL
Rejection Rate:>97%(Organic,colloids,bacteria,and pyrogen are above 99.9% rejected.)
Recovery Rate: 50 ~ 75%
* The better quality of feed water can prolong the membrane life.

Categories  > Ro System
 
( APU889W2-WF14 )
Categories  > Industry Ro System
 
( APM-RO-250/RO-500 )
Operation Pressure: 80 ~ 100 PSI ; "*" REMARKS FOR 150 ~ 220 PSI.
Rejection : 90 ~ 97%
Recovery Rate: 50 ~ 75%

Specifications
Model#

Flow Rates
(GPD)

R.O Modules Model x Numbers

R.O Pump/Voltage

Dimensions (cm)
(L x W x H)

RO-250*

250

2521X1

1/3HP,110V/220V

36X52X118

RO-500*

500

2521X2

1/3HP,110V/220V

36X52X118


Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4
Categories  > Ro System
 
( APU889C1-WF14 )
Categories  > Industry Ro System
 
( APM-DW-RO-1500UO3 DW-RO-6000UO3 )
Operation Pressure: 150 - 220 PSI
Rejection : >90(Organic,colloids,bacteria,and pyrogen are above 99.9% rejected.)
Recovery Rate: 50 ~ 75%

Model

DW-RO-1500U03

DW-RO-3000U03 DW-RO-6000U03

Feed Pump

1HP

1HP 1HP

Iron Removal Filter

MS-60L SS-60L

MS-80L SS-80L MS-100L SS-100L
Activated Carbon Filter AC-1500L AC-3000L AC-6000L
Softener (include Brine Tank) AC-60L AC-80L AC-100L
RO System SA-1500 SA-3000 SA-6000
UV Sterilizer S12Q S12Q S12Q
Ozone Generato OWA-500 OWA-1000 OWA-1000
Distribtion Pump Stainless Steel Stainless Steel Stainless Steel
Dimension Length:240cm
Width:75cm
Height:180cm
Length:260cm
Width:75cm
Height:180cm
Length:300cm
Width:75cm
Height:180cm


Feedwater Conditions
* Feed Water Pressure=1kg/cm2~3kg/cm2
* Chlorine = < 0.5 ppm
* Total Hardness = <150 ppm
* Turbidity =< 2
* Fe = < 0.1 ppm
* Flow Rate > 1 T/hr
Operation Pressure:150~220PSL
Rejection Rate:>97%(Organic,colloids,bacteria,and pyrogen are above 99.9% rejected.)
Recovery Rate: 50 ~ 75%
* The better quality of feed water can prolong the membrane life.

Categories  > Industry Ro System
 
( APM-LA - 5000 ~ LA -10000 )
Operation Pressure : 150 -220 PSI
Rejection : >97% (Organic, colloids, bacteria, and pyrogen are above 99.9% rejected.)
Recovery Rate: 50% ~ 75%

Model#

Flow Rates (GPD)

R.O Modules
(Model x Numers)

R.O Pump / Voltage

Pre - Filter

Dimensions (cm)
& Weight (kg)

LA - 6000
LA - 7500
LA - 9000

6000
7500
9000

4040*2
4040*3
4040*4

3HP,220V/380V
5.5HP,220V/380V
5.5HP,220V/380V

TK10 * 1
TK10 * 1
TK10 * 1

210*70*178
210*70*178
210*70*178


Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4
Categories  > Industry Ro System
 
( APM-LBW-35 ~ LBW-70 )
Operation Pressure : 150 -220 PSI
Rejection : >97% (Organic, colloids, bacteria, and pyrogen are above 99.9% rejected.)
Recovery Rate: 50% ~ 75%

Model#

Flow Rates (GPD)

R.O Modules
(Model x Numers)

R.O Pump / Voltage

Pre - Filter

Dimensions (cm)
& Weight (kg)

LBW - 35
LBW - 50
LBW - 70

21000
30000
42000

4080*2
4080*3
4080*4

5.5HP,220V/380V
7.5HP,220V/380V
15HP,220V/380V

TK14 * 1
TK21 * 1
TK21 * 1

230*80*178


Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4
Categories  > Industry Ro System
 
( APM-RO-200A/RO-200N/RO-300A/RO-300N )
Operation Pressure: 80 ~ 100 PSI ; "*" REMARKS FOR 150 ~ 220 PSI.
Rejection : 90 ~ 97%
Recovery Rate: 50 ~ 75%

Specifications
Model#

Flow Rates
(GPD)

R.O Modules Model x Numbers

R.O Pump/Voltage

Dimensions (cm)
(L x W x H)

RO-200

200

75GX2

110V/220V

45X18X88

RO-300

300

75GX3

110V/220V

45X18X88


Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4
Categories  > Ro System
 
( APU889C3-WF14 )
Categories  > Industry Ro System
 
( APM-DW-RO-9000UO3 )
Operation Pressure: 150 - 220 PSI
Rejection : >90(Organic,colloids,bacteria,and pyrogen are above 99.9% rejected.)
Recovery Rate: 50 ~ 75%

Model

DW-RO-9000U03

Feed Pump

1.5HP

Iron Removal Filter

MS-120L SS-120L

Activated Carbon Filter AC-120L
Softener (include Brine Tank) SD-120L
RO System SA-9000
UV Sterilizer S24Q
Ozone Generato OWA-1000
Distribtion Pump Stainless Steel
Dimension Length:320cm
Width:85cm
Height:180cm


Feedwater Conditions
* Feed Water Pressure=1kg/cm2~3kg/cm2
* Chlorine = < 0.5 ppm
* Total Hardness = <150 ppm
* Turbidity =< 2
* Fe = < 0.1 ppm
* Flow Rate > 1 T/hr
Operation Pressure:150~220PSL
Rejection Rate:>97%(Organic,colloids,bacteria,and pyrogen are above 99.9% rejected.)
Recovery Rate: 50 ~ 75%
* The better quality of feed water can prolong the membrane life.

Categories  > Industry Ro System
 
( APM-RO-3000H/RO-4500H )
Operation Pressure: 80 ~ 100 PSI ; "*" REMARKS FOR 150 ~ 220 PSI.
Rejection : 90 ~ 97%
Recovery Rate: 50 ~ 75%

Specifications
Model#

Flow Rates
(GPD)

R.O Modules Model x Numbers

R.O Pump/Voltage

Dimensions (cm)
(L x W x H)

RO-3000H*

3000

4040X2

3HP,110V/220V

60X48X180

RO-4500H*

4500

4040X3

3HP,110V/220V

60X48X180


Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4
Categories  > Ro System
 
( APM-RO-50/75A APM-RO-50/75N )

Operation Pressure: 80 ~ 100 PSI ; "*" REMARKS FOR 150 ~ 220 PSI.
Rejection : 90 ~ 97%
Recovery Rate: 50 ~ 75%

Specifications
Model#

Flow Rates
(GPD)

R.O Modules Model x Numbers

R.O Pump/Voltage

Dimensions (cm)
(L x W x H)

RO-50A

50

50GX1

110V220V

35X20X45

RO-50N

50

50GX1

110V/220V

35X20X45

RO-75A

75

75GX1

110V/220V

35X20X45

RO-75N

75

75GX1

110V/220V

35X20X45

Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4


Categories  > Industry Ro System
 
( APM RS-250 ~ RS-800 )
Operation Pressure : 150 -220 PSI
Rejection : >97% (Organic, colloids, bacteria, and pyrogen are above 99.9% rejected.)
Recovery Rate: 50% ~ 75%

Model#

Flow Rates (GPD)

R.O Modules
(Model x Numers)

R.O Pump / Voltage

Pre - Filter

Dimensions (cm)
& Weight (kg)

RS - 250
RS - 500
SR - 800

250
500
800

2521*1
2521*2
4021*1

1/3HP,110V/220V
1/3HP,110V/220V
1/2HP,110V/220V

5µm, 20" * 1

1µm, 20" * 1

73*40*113*56
73*40*113*58
73*40*113*60


Feedwater Conditions
Inlet Pressure ------------- > 1.5 kg/cm2
Chlorine -------------- < 0.1 ppm
Total Hardness ----------- <10 ppm
Turbidity ------------- < 2 NTU
Fe ----------------------------- < 0.1 ppm
SDI -------------------- < 4

 


Address :  1F., No. 39, Fu An 10 Street, Shi-Tun Dist.,Taichung, Taiwan 407
Telephone :  +886-4-2359-7300
Fax :+886-4-2359-7305  Website :  www.airpower.com.tw  
E-mail : email@airpower.com.tw 

Designed by Web Builder & Trade Associated with AsianNet